Horizontal double suction volute split case pump

Double Volute Horizontal Split Case On Springer Pumps, LLC The HSC pump is a horizontal, single stage, double suction, double volute axially split case centrifugal pump. The suction and discharge nozzles are integrally cast in the lower half of the casing and on the same horizontal centerline. The nozzle configuration is side/side. OPERATION LIMITS. Capacity up to 31,800 m 3 /h (140,000 U.S. gpm)

[PDF]SPLIT CASE Double Volute, Horizontal Split Case Pumps SPLIT CASE Double Volute, Horizontal Split Case Pumps. Ruhrpumpen is an innovative and efficient centrifugal pump technology company that offers operators of Pump Systems a wide range of quality products. Split Case Pumps. The Ruhrpumpen HS/ZW pumps are single- or multi- stage, double suction, double volute, axially-split case pumps.文件大小: 856KB

Horizontal - Multistage - Double Case - HDO and HSO The inner volute case is a double volute design, which split in two identical halves. The horizontal split parting faces are processed to provide a perfect seal without a gasket. The inner case is subject to compressive stress only and only light bolting along the split is required, which greatly facilitates dismantling.

Pros & Cons of Horizontal Split-Case Pumps Pumps & Systems Typically these pumps offer dual volute construction, which significantly reduces the radial thrust component. Disadvantages of HSC pumps: The pump is sensitive to horizontal elbows on the pump’s suction side. Fluid flow through the horizontal elbows induces asymmetrical pressures on the impeller that lead to shortened bearing and seal life.

[PDF]Series SC-II Horizontal Split Case Pumps - Federal Pump Split Case single stage double suction centrifugal pump designed to deliver the scheduled flow rate (GPM) at the scheduled total dynamic head (TDH) in feet. Pump will be sized to be non-overloading throughout the full range of

HS horizontal split case pumps Grundfos The Grundfos HS horizontal split case pump is a single-stage, non-self-priming, between bearing, centrifugal volute pump. The axially split design allows easy removal of the top casing and access to the pump components (bearings, wear rings, impeller, and shaft seal) without disturbing the motor or pipework.

Axially split pumps Sulzer The HSA API 610 (ISO 13709) Type BB1 is an axially split, single stage, horizontal, double suction, between bearing pump. The Sulzer HSA product range is ideal for long term continuous running services in refineries and pipelines.

[PDF]OPERATION & MAINTENANCE MANUAL for DOUBLE This manual covers the installation, operation and maintenance of Patterson Pump horizontal split case pumps. The pump is a centrifugal, single stage, double suction type. When properly installed and when given reasonable care and maintenance, centrifugal pumps should operate satisfactorily for a long period of time.文件大小: 1MB

[PDF]00.Horizontal Split Case LN Type - Sterling Pumps The pump shall be a horizontal, single stage, double suction, double volute axially split case centrifugal pump. The suction and discharge nozzles shall be integrally cast in the lower half of the casing and on the same horizontal centerline. The pump shall have a side suction and discharge equal to the LN type pump.文件大小: 2MB

Split case pump, end suction pump, double suction pump Hankia Pump supply both the end suction pump and axially split case double suction pump. So there are often multiple pump types that can be selected for the same water application, with each pump type having its own strengths and weaknesses.

Double Volute Horizontal Split Case On Springer Pumps, LLC The HSR pump is a horizontal, single stage, double suction, double volute axially split case centrifugal pump. The suction and discharge nozzles are integrally cast in the lower half of the casing and on the same horizontal centerline. The nozzle configuration is side/side. OPERATION LIMITS. Capacity up to 2,050 m 3 /h (9,000 U.S. gpm)

PACO Horizontal Split Case Pumps: KP Grundfos KP Horizontal Split Case pump. Double suction minimizes axial load, which extends the life of the wear rings, shaft seals and bearings; Double volute reduces radial forces and minimizes noise and vibration; Independent bearing housing design allows access to the pump components without removing the top half of the casing

S Volute Type Horizontal Split Case Double Suction S Volute Type Horizontal Split Case Double Suction Centrifugal Pump , Find Complete Details about S Volute Type Horizontal Split Case Double Suction Centrifugal Pump,Split Case Pump,Split Casing Pump,Double Suction Pump from Pumps Supplier or Manufacturer-Shanghai Pacific Pump Manufacture (Group) Co., Ltd.

Axially split case pump, horizontal, vertical, singel Axially split case pump that the volute casing is axially split have single stage and multistage pump, two main types. The single stage (horizontal and veritcal) axially split case pump usually have double suction impeller. The multistage split case pump usually has double suction impeller for the first stage.

Horizontal Between Bearing Centrifugal Pumps, Split Case The SM pump model is a heavy-duty, horizontal, axial split casing, volute type, multi stage, centrifugal pump according to the API 610 Capacity 50 to 3,000 m³/h (220 to 13,209 gpm) Head 200 to 3,000 m (656 to 9,843 ft)

Standart Pump / Single stage volute type horizontal pumps Close-coupled pumps ( fits to DIN 24255 ), Sewage & drainage pumps, In-line pumps ( fits to DIN 24255 ), Thermal-oil pumps with air cooled, Booster sets, Special liquid pumps, Double suction split case pumps, Drip irrigation pumps and systems, Drinking water and domestic pumps and systems

End-Suction pump vs Horizontal Split Case - Fire The durability of the horizontal split case pumps design allows the pump to be used for very large water flows in excess of 5000 gpm as the pump casings are often heavier and designed to handle higher working pressures, moreover, the design of "Impeller between bearing" and since the water enters the two sides of the impeller (double suction), these pumps can withstand

[PDF]00.Horizontal Split Case LN Type - Sterling Pumps 8.5 Typical LN pump specifications General (LN type) The pump shall be a horizontal, single stage, double suction, double volute axially split case

Single-stage axially split volute casing pump KSB Single-stage axially split volute casing pump for horizontal or vertical installation, with double-entry radial impeller, mating flanges to DIN, EN or ASME. Application Pumping water with a low solids content, e.g. in waterworks, irrigation and drainage pumping stations, extraction duties in desalination systems, power stations, fire-fighting

[PDF]Double suction centrifugal split case pumps DPAS pumps are double suction, horizontal split case pumps. Since the upper cover of the pump is removable, all internal components can be easily replaced without disassembling the pump from the piping. Stuffing box is cooled with water. Seals are easily dismountable, which makes replacing and fitting up additional seals easy. Since the

Horizontal Split Casing Pumps 3D Installation Manual - YouTube May 07, 2012· An animated installation manual of Sintech made Horizontal Split Casing Pumps. sintech.in. Axial Split Case Double Suction Pump - RDP - Duration: 5:51. Think Smart! 32,261 views.

SCTE (split case BB1) - Rodelta - Rodelta Pumps International Pump Casing: Horizontal axially spilt volute type, suction and discharge nozzles and supporting feet are cast integral with lower half casing. Impeller: Double or single suction type accurately balanced. In case of double suction impellers, the hydraulic thrust is balanced automatically because of pressure equalization on both sides of the

Double Suction, Horizontal, Split Case Centrifugal Pump The PS Series is a double suction, horizontal, split case centrifugal pump available in 46 sizes from 5x3-8 (125x80-210) to 36x36-31 (900x900-780) for heads up to 656 feet (200 m) and flows up to 80,000 GPM (18,000 m 3 /hr.). The PS Series has a maximum operating pressure of 435 PSI (30 bar) and a maximum operating temperature of 221° F (105° C).

Double-suction pump KSB In double-suction pumps the total flow rate is distributed over several impellers arranged on a pump shaft. The head remains constant The most common type of multi-suction design in centrifugal pump engineering is a double-suction pump whose impeller pair is arranged back to back on the pump shaft (see Back-to-back impeller pump).This arrangement serves to